建筑给排水管道施工毕业论文

1.建筑给水排水工程毕业设计摘要外文翻译,求高手

The main elements of the design include: the design of building water supply system, fire fighting system design of building water supply and drainage system design, architectural design and building hot water system. Through this graduation design, can make oneself more system, complete the professional knowledge in practice, cultivate their ability of comprehensive ability and engineering practice and related knowledge. Water supply system using zoning method. The basement and one or two floors on the ground by the municipal water supply pipe network, using downfeed type. Three to twelve layer by the pool, the water pump and the tank joint water supply, using downfeed distribution. Through comparative analysis, drainage system, drainage system. Hot water supply system by hot water distribution network and a return pipe. Fire water supply safety and reliability requirements of the building, fire hydrant system and automatic sprinkler system independence. 求追分 打了我好久。

2.高价求高人 做 一篇建筑给排水毕业设计

建筑给水排水设计说明

一、设计资料

(1) 建筑资料

建筑各层平面图、建筑剖面图、厨厕大样图等。

建筑物为六层住宅,采用钢筋混凝土框架结构,层高为3M,

室内外高差为0.3M。

(2) 水源资料

在建筑物南侧有城市给水管道和城市排水管道(分流制),据调查了解当在夏天用水高峰时水压为270kPa。每户厨房内设洗涤盆一个,厕所内设蹲式(或坐式)大便器,洗脸盆、淋浴器(或浴盆)及用水龙头(供洗衣机用)各一个。每户设水表一个,整栋住宅楼设总表一个。

二、设计内容

1. 设计计算书一份,包括下列内容

(1) 分析设计资料,确定建筑内部的给水方式及排水体制。

(2) 考虑厨厕内卫生器具的布置及管道的布置与敷设。

(3) 室内外管道材料、设备的选用及敷设安装方法的确定。

(4) 建筑内部给排水系统的计算。

(5) 其他构筑物及计算仪表的选用、计算。

(6) 室外管道定线布置及计算(定出管径、管坡等数据及检查井底标高,井径,化粪池进出管的管内底标高等)。

2. 绘制下列图纸

(1) 各层给排水平面图(1:100)。

(2) 系统原理图。

(3) 厨厕放大图(1:50)。

(4) 主要文字说明和图例等。

三、设计说明

1、给水工程

根据设计资料,已知室外给水管网常年可保证的工作水压270kPa,建筑物六层住宅估算

水压:120+40*4=280kPa,故室内给水拟采用直接给水方式。

2、排水工程

为减小化粪池容积和便于以后增建水中水工程,市内排水系统拟使生活污水和生活废水分质分流排放,即在每个竖井内分别设置两根排水立管,分别排放生活污水和生活废水

3、管道的平面布置及管材

室外给水排水管道平面布置见首层平面布置图。进户管布置在室外,。采用一户一表。,水表选用LXS湿式水表。水表内装在厨房,但每个单元门口都装备传感器以显示用水量。室内给水、排水立管均靠墙布置。给水水平干管、排水横干管均埋地布置。给水管采用u-pvc给水塑料管。排水管用PVC塑料管。

4 管道的敷设及连接方式

给水管刚入户时明装,通过厅堂、厨房、卫生间时均采用暗装方式。给水管和排水管均采用橡胶圈连接方式。

5 洗涤盆和洗脸盆安装高度为0.8M,淋浴器安装高度为2M,低水箱坐式大便器水龙头安装高度为0.51M,洗衣机用水龙头安装高度为1.5M 。

四 设计计算

1 室内给水系统的计算

(1)给水用水定额及时变化系数

因为住宅内有大便器、洗涤盆和沐浴设备,因此设定每人每日生活用水定额(最高日)为200L,小时变化系数为2.8。预测平均每户住4人,则最高日用水量

[1] [2] 下一页

本文来自: 一流设计吧() 详细出处参考:

3.给水排水专业毕业论文咋写,结合城市官网建设与资源可持续的

给水排水专业写的方向很多,我开始也没法下手,还是同学给的莫'文网,靠谱的说

居住小区与建筑内部热水设计秒流量计算方法

概率方法对居住小区设计秒流量的推求

市政给水管网模拟演示系统开发

西部小城镇环境基础设施经济指标研究

NCAF涡凹型气浮设备的开发及应用研究

秦王川盆地南部地下水数值模拟研究

上海世博园大型地表水源热泵对黄浦江水环境的影响

昆明城中村改造对资源环境承载力和基础设施的影响

水体在南方郊野公园中优化设计研究

曝气生物滤池(BAF)计算机辅助设计

三峡库区山地小城镇生活污水沟渠强化处理的试验

湖北省农村生活污水水量水质调查与分析

个旧锡矿高峰山矿段开采期渗流场数值模拟及涌水量预测

IGCC电站工艺系统设计分析与热力学系统

基于ArcGIS的地下管线三维虚拟仿真研究与实现

三峡库区典型农村生活污染负荷计算及处理方法

生态村水环境承载力系统评价研究

沿海低地城市道路建设中环境工程设施配置研究

基于控规的区域建筑能源需求分析

钢筋混凝土矩形隔震贮液结构液固耦合地震响应

某金融港及市民服务中心项目可行性研究

陕西省农村绿色基础设施评价指标体系的构建

周进周出辐流式沉淀池配水系统水力计算

基于建构绿色基础设施维度的城市河道景观规划研究

寒地既有村镇住宅厨卫设施功能提升技术研究

基于城市水健康循环的哈尔滨江段防控体系构建

住宅配套设施综合效益评价研究

黄土高原沟壑地区山村聚落的空间形态

大型双吸离心泵径向力数值计算

城市地下基础管网特许经营BOT模式研究

城市管网三维模型的设计与实现

基于GIS的校园管网管理系统的设计与实现

新时期村庄建设规划理论和方法研究

陕西省农村基础设施投资效果评价体系

矩形混凝土水池与地基共同作用设计理论和方法

4.求【给水排水工程】【英文】论文

The multilevel residential housing is given and drains off water several questions designed Summary: This text give and drain off water on multilevel residential housing design supply water the exertion of the tubular product , Way of laying of pipeline, water gauge produce family set up, establishment and air conditioner condensation water of pot-type boiler discharge issue goes on the discussion , And put forward some concrete views. Keyword: Skyscraper, supply water the tubular product , the pipeline is laid, The water gauge, the solar water heater The skyscraper is simple with its auxiliary facility, the fabrication cost is low, the characteristic such as being convenient of estate management, Receive the welcomes of the real estate developer and vast resident of small and medium-sized cities very much. How project planning and design of inhabited region, scientific and technological industry of comfortable house, lead the request according to 2000, Improve the design level of the house, build out a comfortable living space for each household, It is each designers duty. As the heart of the house --The kitchen, bathroom, is that the function is complicated, hygiene, safe and comfortable degree are expected much, It is miscellaneous to build, the space expecting much in technology. So, the designer must consider synthetically with the idea and method of global design that the kitchen, bathroom give installation of the drainage pipeline and equipment, etc. Give and drain off water on skyscraper design supply water exertion, to lay pipeline of tubular product, water gauge produce family set up, establishment and empty of pot-type boiler now Transfer condensation water discharge issue discuss together with colleagues. ( 1), supply water tubular product select problem for use Traditional water supply tubular product adopt zinc-plated steel tube generally, because zinc-plated steel tube exchange the corrosion, Use short-lived , use for and send domestic water can satisfied with water quality sanitary standard shortcoming, Ministry of Construction is popularizing the application of the feed pipe of plastics energetically . A lot of districts and cities have already expressed regulations: Forbid designing and using the zinc-plated steel tube , use widely the feed pipe of plastics. The plastics supply water In charge of compared with metal pipeline, light, it is fine to able to bear the intensity of keeping, Send obstruction little liquid , able to bear chemistry better to corrode performance, it is convenient to install, The steel energy-conservation of the province, merit of having long performance life etc.. Supply water and use plastics pipeline: Hard polyvinyl chloride( PVC-U), high density polyethylene( HDPE), pay and unite polyethylene( PEX) , modify the polypropylene( PP-R, PP-C), gather butane( PB), aluminum mould and compound and in charge of and the steel is molded and compound and is managed etc.. Choice of tubular product economic comparative course of technology, technology should from pressure, temperature, environment for use, install method ,etc. go on and consider, Combine owners at the same time request and the house of grade, carry on and fix after being consider synthetically technology not economic. The above plastics supply water tubular product can supply water tubular product as house life. The economic and functional house conciliating Strand room in the face of the masses of with low- and medium-level incomes resident, can select for use hygiene grades of hard polyvinyl chloride in charge of as feed pipe mainly, In order to reduce the fabrication cost; Medium-to-high grade commodity apartment available aluminum Mould and compound and in charge of or other plastics supply water the tubular product as the feed pipe. House mix hot water temperature that water order exceed 600 C, so above-mentioned tubular product in charge of except hard polyvinyl chloride and aluminum plastics compound and in charge of( PE-AL-PE), Mostly the tubular product can be regarded as the hot water pipeline of the house.。

5.急求建筑给排水质量要求和现场管理的论文

浅析建筑给排水质量通病及其防治摘要 从施工角度分析建筑给排水工程中管道渗漏、管道穿越楼(地)板处的渗漏、管道沟槽开挖后槽底泡水、施工过程中管道堵塞、管道支架不牢固、给水立管安装、给水系统消毒、卫生洁具安装等问题产生的原因,并提出了防治办法。

关键词 建筑给排水 质量通病 防治建筑给排水工程是建筑工程的重要组成部分,其质量的好坏直接影响着建筑工程质量,如当前建筑工程中经常存在的地面渗漏、管道易堵等水卫设备安装通病往往影响到整个工程的交付使用,所以,必须予以重视。笔者对上述质量通病做了些调查,就其产生原因及克服办法谈几点意见,仅供施工人员参考。

1 管道渗漏问题建筑给排水中管道漏水是常见的质量通病。原因众多:一是所用材料不合格,如所选用的PPR及PVC-U管质量达不到国家标准,管材阀门本体与阀芯、阀盖之间密封性差等造成内漏和外漏,或以次充好。

这样就要求把好材料选用关,要审查确定合格供应商,按质量标准对进场材料严格进行复验,对管材、阀门应逐一进行试压;二是管道连接操作不当,如用螺纹连接时,加工的螺纹与配件不配套或螺纹密封材料失效,或是连接不严密使用时容易发生渗漏;三是把好连接的操作关,无论是螺纹、焊接还是法兰承插式、热熔等连接,都应采用正确的操作方法严格规范施工,达到质量标准。2 管道穿越楼(地)板处的渗漏问题建筑给排水工程常用的管材主要有钢管、铸铁管和塑料管。

按照《建筑给水排水及采暖工程施工质量验收规范》(GB 50242—2002)的规定,铸铁管、塑料管一般采用直接穿越楼(地)板的方式施工,钢管采用设置钢制套管的方式施工。铸铁、塑料下水管道常用的施工方法有随主体一起施工和预留孔道以后穿管两种方法。

这两种方法都存在管道与楼(地)板接触部分的严密性问题, 如果施工处理不当而出现空隙,则势必造成漏水。较好的处理方法是:对于管道随主体一起施工的工程,应在土建再做防水找平层之前涂抹防水涂料2遍,然后土建做防水找平层及防水层;对于预留孔洞的施工方式,应在管道固定时于管道周围25 mm范围内用1∶2水泥砂浆灌严(砂浆应掺UEA微胀剂),砂浆应灌注成八字形,土建所做面层应在管道周围成20 mm高的台形(见图1);使用塑料管道穿楼(地)板时,除注意上述问题外,还应注意将嵌在楼板内的塑料管壁打毛,以利于管道外壁与混凝土的粘结,减少裂缝产生的可能性。

给水工程和热水工程常采用穿套管过楼(地)板的方法,为了方便施工,套管埋设一般采用预留孔洞的方式,具体做法可参考排水立管预留孔洞穿楼(地)板的方法。套管穿楼板时除注意与楼板接触严密外,还应注意:套管一定采用钢管,不得以镀锌皮管代替,且套管直径应比所穿管道大两号,套管长度应比楼板厚多20 mm,以保证安装时上端高出楼板20 mm,下端与楼板齐平。

另外,套管与管道之间的缝隙应采用聚氨酯、沥青玛蹄脂等材料封严。3 管道沟槽开挖后槽底泡水问题施工过程中由于各种原因,如:天然降水或其他客水流进沟槽;对地下水或浅层滞水,未采取排降水措施或排降水措施不力。

这样会造成槽基被浸泡后,地基土质变软,会大大降低其承载力,引起管渠基础下沉,造成管渠结构折裂损坏,对此施工中应采取预防对策:①雨季施工,要将沟槽四周叠筑闭合的土埂,必要时要在埂外开挖排水沟,防止客水流入槽内。②下水道接通河道或接入旧雨水管渠的沟段,开槽应在枯水期先行施工,以防下游水倒灌入沟槽。

③在地下水位以下或有浅层滞水地段挖槽,应使排水沟、集水井或各种井点排降水设备经常保持完好状态,保证正常运行。④沟槽见底后应随即进行下一道工序,否则,槽底以上可暂留20 cm土层不予挖出,作为保护层。

如槽底已泡水时,应从两个方面采取对策:①沟槽已被泡水,应立即检查排降水设备,疏通排水沟,将水引走、排净。②已经被水浸泡而受扰动的地基土,可根据具体情况处置。

当土层扰动在10 cm以内时,要将扰动土挖出,换填级配砂砾或砾石夯实;当土层扰动深度达到30 cm但下部坚硬时,要将扰动土挖出,换填大卵石或块石,并用砾石填充空隙,将表面找平夯实。4 施工过程中管道堵塞问题施工过程中,由于管道开口处封堵不当,极容易造成水泥砂浆和其他建筑垃圾进入管道,很难清理,以致使用后经常出现排水管道堵塞。

对此,施工中应从两个方面采取对策:一是封口的质量一定要保证,如采用木塞或用薄钢板制成堵头,钢板上用石灰砂浆而不用水泥砂浆封堵(水泥砂浆易破碎,进入排水管后不易清除);二是在施工过程中不盖立管最下部的排水检查口,在管内设置导物槽(见图2),这样,立管内的杂物即可经导物槽排出,而不致进入底部的排水横管。导物槽宜采用厚度大于3 mm的钢板制作。

5 管道支架不牢固问题目前工程中给水系统大多采用PPR管,由于其刚性差,加之施工时不注意支架的安装,会造成管道弯曲、变形,甚至出现渗漏现象。支架间距严格按照规范规定设置;支架安装严格按照施工工艺要求进行施工。

而目前工程中排水管大多采用PVC-U管,与钢管相比其刚。

6.要一篇中英双语论文 建筑给水排水

MECHANICAL PRELIMINARY DESIGN REPORT STADIUM 1.给排水设计 饮用水和污水 1.Sanitary Design Water and sewage water .设计基础 - 甲方提供的设计任务书和市政管网综合图 - 建筑专业提供的条件图 - 国家现行的设计规范及有关规定设计简章 .Design bases Design Brief and Municipal integrated network drawing offered by the client. Condition drawings from architectural discipline. Current national design codes and related stipulations 2. 给水系统 通过一根DN200的进水管将水引入.水表安装在进水管上,离红线1米处.供水管在红线内连成环路管网,并接到供应楼的消防水池和给排水水池.由环路管网向必需的室外消火栓和绿化带的喷淋器供水. 2. Water supply system For water supply of this project, DN200 water intake pipes are led in. Water meters are installed on the intake pipes 1.0 m away from the red line. The water supply pipes are connected into loop networks in the red line and then led to the fire pool and sanitary water pool in the supply buildings respectively. Necessary number of outdoor hydrants and sprinklers for green area will be provided on the loop networks. 设计范围 包括红线内的饮用水,污水,雨水,建筑消防. Design scope Design scope of this project includes water, sewage water, rainwater, fire-protection in the building, and water and sewage water within the red line. 给排水水池与消防水池分开,容量为100m3 .体操馆供水管埋地敷设. Sanitary water pool is separated from fire water pool, volume of sanitary water pool is 100m3. Water supply pipes for the stadium will be laid in the earth. 3.用水量标准 - 体育馆: 15升/顾客·日 K=2.0 - 宾馆: 150升/人·日 K=2.0 - 餐厅: 50升/顾客·日 K=2.0 - 工作人员: 25升/人·日 K=2.0 - 地面冲洗用水: 3升/m2日 - 冷却塔补水量:按用水量的2%计 - 未预见水量: 按日用水量20%计 - 消防用水: 消火栓:室内40升/秒,室外30升/秒,火灾延续时间为3小时; 自动喷洒按22升/秒,火灾延续时间为1小时 卷帘水幕用水0.5升/秒·米,火灾延续时间为3小时; Water consumption standard - Stadium: 15L/visitor·day K=2.0 - Hotel: 150L/visitor·day K=2.0 - Restaurant: 50L/customer·day K=2.0 - Staff 25L/person·day K=2.0 - Floor cleaning: 3L/m2·day Make-up water for cooling tower: 2% of the actual cold water consumption. Unforeseen water consumption: 20% of the daily water consumption. Water for fire protection Hydrant: 40L/s indoor, 30L/s outdoor, fire duration time is 3h; Sprinkler: 22L/s, fire duration time is 1h; Drencher for rolling shutter: 0.5L/s·m, fire duration time is 3h; 在适当的位置设置饮用水机,在主进口为残障人设置两个饮用水机.为此饮用水系统安装循环泵.机房 设在地下室的水除了机房.当饮用水机不被使用时,应排空,以免水质腐败. 在客房和餐厅内设置电热水器,同时亦为热水供应设置循环泵. 在更衣间旁设置电热水器,为淋浴和洗盥供应热水. 为楼板清洁安装一定数量的水龙头. Some suitable places are supplied with portable water drinking units, two drinking units for disable people are provided at main entrances, for this portable water system, circulating pumps are adopted, the equipment room is located in water treatment center in the basement. When there is no use, portable water will be drained completely to avoid deterioration. Electric water heaters are installed in guest rooms and restaurant, also hot water circulating pumps will be provided for supplying hot water. Electric water heaters are installed near the changing and clothing rooms for supplying hot water for shower and washing. Certain number of water taps are installed for floor-cleaning. 4.用水量 最大日用水量:2.200m3/日 最大时用水量:220m3/时 Water consumption demand Maximum daily water consumption: 2.200m3/day Maximum hourly water consumption: 220m3/hour 却循环系统 冷却水循环系统采用机械循环系统.总冷却水用量为460m3/h.在供应楼顶设置三台超低噪音冷却塔(230 m3/h, 2x 115 m3/h).进水温度37Co,出水温度32Co .补充水量 9,6 m3/h.补充水由市政供水网直接提供. Cooling water circulation system There are cooling water circulation system in this project, cooling water for the refrigerators adopts mechanical circulation system. Total water consumption of cooling towers is 460m3/h. On roof of the supply building there are 3 ultra-low noise cooling towers (230 m3/h, 2x 115 m3/h), inlet temperature of 37Co, outlet temperature of 32Co, with make-up water of 9,6 m3/h. Make-up water of the cooling towers will be supplied directly by the municipal network. 在消防泵房内有消火栓泵(一个运行,一个备用),喷淋泵(一个运行,一个备用),卷帘雨淋泵(一个运行,一个备用).用于地下车库的泡沫喷淋设备,如报警阀,泡沫压缩罐,化学药剂泵安装在消防设备中心。

7.结合自己的专业(土木工程),谈谈你对《建筑给水排水工程》这门

2300字。

你可以结合你学的知识稍微做一下修改。建筑给排水学习心得 水是人民生活、生产必备的资源。

没有水源的建筑物是不具备使用功能的。作为建筑物必不可少的一部分,水又扮演着一个十分重要的角色。

其中最基本,也是最重要的就是给水 、排水和消防工程。有的高档的小区有中水系统,可以直接把生活的污水加以利用。

消防工程是为了在火灾的初期和中期对火灾加以控制,在消防车达到之先进行灭火。排水系统时将人们生活生产产生的污水废水排出建筑物,送到污水处理厂的一套系统。

给水系统是为人民提供生产生活比不可少的水资源。在不同的地区、不同的小区里,不同的水,被送到个个房间里。

一个完整的建筑物必不可少有给水排水系统和消防工程。下面我就我对这门课的心得体会,从给水方式,排水方式两方面谈一谈。

一.给水方式 建筑物的内部给水方式的选择应按以下原则进行;给水系统简单,管道长度短,安全可靠管理维修方便,外网的压力, 1.常见的给水方式有以下几种。 (1) 直接给水方式。

建筑物内部有给水管道,部设有升压设备,直接由外网给水。这种给水方式简单,投资少,充分利用外网压力,安装维修方便。

缺点系统无贮水设备。(2) 单设水箱给水方式。

在建筑物的内部设有管道系统和屋顶水箱,且室内给水系统与室外的给水系统相连接。当室外外网的压力能够满足室内用水时,则由室外管网向室内给水,并向水箱供水,当用水高峰期时,室外的压力不足时,则由水箱向室内供水。

这种供水方式的一定范围上解决了供水的不足。但是系统设置了水箱,增加了建筑物的结构荷载。

(3) 水泵水箱联合给水方式。当室外水管网水压经常不足、室内用水不均匀、室外管网不允许直接有水泵吸水且建筑允许设水箱时,可以用这种给水方式。

有了水泵的加入,工作效率提高了,增强了供水的可靠性。(4) 变频调速水泵给水。

变频调速水泵的工作原理是当给水系统的流量变化时扬程也随着变化。这样的设备在一定程度上节约了电。

(5) 分区给水方式。当建筑物大的高度增加到一定高度前面的给水方式都不适合。

这时我们可以把建筑物的高度分成若干个区,分区给水分区以后产生一些弊端:管材零件配水器的费用增加。容易产生水锤及水锤噪声影响材料的使用寿命。

高层建筑给水是建筑中比较特殊的。高度就是对给水系统是一种考验。

高层建筑的给水方式有 1高位水箱 2无高位水箱 3气管给水。高位水箱又有三种方式1串联给水方式2并联给水方式3减压给水方式 无高位水箱的又有2种1串联给水方式2并联给水方式2.给水所用的管材:(1)镀锌钢管曾经是我过生活饮用水采用的主要管材由于其内壁容易生锈、结垢、滋生细菌、微生物等有害物质,会对自来水造成二次污染,可以采用焊接、螺纹连接、法兰连接或卡箍连接。

优点是强度高、抗震性好。(2)不锈钢管优点机械性好、坚固、韧性好、卫生条件好。

可采用焊接、螺纹连接、卡压式卡套式等连接。(3)铜管优点耐温、延展性好、承压能力好化学性质稳定、线性膨胀系数小。

可用螺纹连接 、焊接、法兰连接。(4)应聚氯乙烯管优点:耐腐蚀好、抗老化性好价格便宜。

通常采用承插粘接也可以用螺纹连接、法兰连接。(5)聚乙烯管优点:重量轻 韧性好 耐腐蚀 耐低温 良好的抗菌性 连接采用电熔热熔橡胶圈连接。

(6)交联聚乙烯管交联聚乙烯管具有强度高 韧性好 抗老化(使用寿命50年以上)采用卡套式连接和卡箍式连接。目前,广泛采用新型建筑给水塑料管而淘汰镀锌钢管。

铜管仍是高档住宅的首选,但价格高。一般在热水系统中采用带保温套的紫铜管、聚丁烯管(PB管)、铝塑复合管(PEX-AL-PEX)、PEX管、PPR管等。

UPVC管和PE-AL-PE管适用于冷水供水系统。建筑物所用的给水管材和给水方式应该相匹配。

这样才能使建筑材料发挥其实用功能,也可以使建筑物的成本减低。我觉得建筑的设计单位应该为业主考虑。

二.排水方式 高层建筑层数多,高度较大,多根横管同时向立管的几率较大,排水落差大,更容易造成管道中的压力的波动。因此高层建筑为了保证排水的通畅和通气良好,一般采用设置专门通气管系统。

有的通气管的排水系统造价高,占地面积大。管道安装复杂,如果能省去通气管,对宾馆、写字间、住宅在美观和经济方面都是非常有益的。

采用单了立管放大管径方式在经济和技术亦不合理。因此人们不断研究新的排水系统。

影响排水立管通水能力的主要因素如下:1从横管流入立管的水流形成水舌阻碍气体,使空气难于进入下部管道造成负压。2立管中形成水塞阻碍空气流通。

3水流到立管地步进入横管是产生水跃阻塞横管。(1)新型的排水系统:1苏维脱排水系统 1961年瑞士索摩研究发明了一种新型的排水立管配件,各层排水横管支管与立管采用水气混合气连接,排水立管采用气水分离器连接,这样达到取消通气管的目的,这种系统别称为苏维脱排水系统。

2.旋流排水系统 旋流排水系统 是法国的勒格、查理和鲁夫于1937年共同发明的。这种排水系统每层的横支管和立管采用旋流街头配件连接,立管底部采用旋流排水弯头连接。

3.芯性排水系统 芯性排水系统是日本小道德厚于1973年发明的。

建筑给排水管道施工毕业论文

转载请注明出处众文网 » 建筑给排水管道施工毕业论文

资讯

机座数控毕业论文

阅读(80)

本文主要为您介绍机座数控毕业论文,内容包括数控技术毕业论文怎么写数控技术毕业论文,我想要一个关于《数控毕业的论文》,谁有数控专业的毕业论文。数控铣刀的分类及应用的研究 摘共l数控行业的空前发展,使数控铣刀样式萦多,对其进行合理划分

资讯

关于erp的毕业论文

阅读(79)

本文主要为您介绍关于erp的毕业论文,内容包括求ERP系统毕业论文,求ERP系统毕业论文,erp毕业论文该怎么写啊。包括论文,设计,论文字数:16137,页数:40 摘要ERP(Enterprise Resources Planning,企业资源计划)

资讯

美术学师范毕业论文

阅读(85)

本文主要为您介绍美术学师范毕业论文,内容包括师范美术专业毕业论文怎么写啊,我是美术学专业国画方向的,过段时间要写毕业论文了,想在近期确,美术鉴赏论文1000到1500字,急求。论文题目:要求准确、简练、醒目、新颖。2、目录:目录是论文中主要

资讯

农村土地流转毕业论文

阅读(76)

本文主要为您介绍农村土地流转毕业论文,内容包括主题为:农村土地流转情况(三千字论文),农村家庭土地流转的论文该怎么写啊范围太大,到底是要,对于土地流转的论文下面的参考文献怎么写。摘要:农村土地流转问题一直是影响农村经济发展的关键因素

资讯

毕业论文字体格式要求国标

阅读(90)

本文主要为您介绍毕业论文字体格式要求国标,内容包括论文的标准格式和字号要求,毕业论文的所有的字号要求是什么,论文格式字体有什么要求。给你个参考 本科生毕业论文(设计)格式要求 第一部分:扉页 论文题目(黑体二号,居中);其他填写内容在

资讯

兰州交通大学地下连续墙毕业论文

阅读(73)

本文主要为您介绍兰州交通大学地下连续墙毕业论文,内容包括求一份关于"地下连续墙施工技术“的完整论文,或者关于地下连续,浅谈地下连续墙施工技术,浅谈地下连续墙施工技术。地下连续墙施工工艺 A地下连续墙施工工艺地下连续墙施工主要施工

资讯

毕业论文培训提纲

阅读(79)

本文主要为您介绍毕业论文培训提纲,内容包括我要写一篇人力资源管理的毕业论文,关于培训的,求一个提纲搜狗,毕业论文的提纲都需要写什么,毕业论文提纲。67. 智联招聘网络甄选体系设计(字数:9293,页数68. 论企业核心竞争力(字数:5137,页数:07 :)69.

资讯

西南交通大学毕业论文封面

阅读(95)

本文主要为您介绍西南交通大学毕业论文封面,内容包括西南交大毕业论文格式是怎样,毕业论文的封面啊什么的怎么弄啊,毕业论文封面格式。毕业论文格式标准 引言 1.1 制订本标准的目的是为了统一规范我省电大本科汉语言文学类毕业论文的格式,保

资讯

中专毕业论文1500字

阅读(84)

本文主要为您介绍中专毕业论文1500字,内容包括中专毕业论文2000字,求中专毕业论文范文,中专生实习毕业论文范文。三年的中专生活似弹指一挥间,从刚跨入中专时的失落和迷茫,到现在即将走上工作岗位的从容、坦然。我知道,这又是我们人生中的一大

资讯

本科毕业论文题库

阅读(83)

本文主要为您介绍本科毕业论文题库,内容包括怎样选择大学毕业论文题目,毕业论文选题,求毕业设计的题目及流程。《毕业论文的选题方法》选题的大小一定要适中,难易要适度.(选题的方法。注意两点:一是选题的大小一定要适中,难易要适度。我们从本

资讯

邮政毕业论文范文

阅读(84)

本文主要为您介绍邮政毕业论文范文,内容包括急需一篇邮政论文2000字的,怎样写关于邮政物流的毕业论文,怎样写关于邮政物流的毕业论文。邮政OA系统工作流控制与管理的研究 企业人力资源管理模式研究兼叙邮政企业人力资源管理模式的实证分析

资讯

音乐教育毕业论文开题报告

阅读(86)

本文主要为您介绍音乐教育毕业论文开题报告,内容包括求:一篇音乐论文开题报告和5000字的有关音乐的论文,音乐专业毕业论文开题报告怎么写,音乐类的论文开题报告怎么写。音乐课题开题报告 课题名称:有效创设教学情境的策略研究 课题的由来 当

资讯

cuda技术毕业论文

阅读(86)

本文主要为您介绍cuda技术毕业论文,内容包括毕业工作方向选择CUDA还是其他可以普遍用到的编程技术呢百度知,我学艺术设计的要雪CAD3DMAX等等CPU用AMD的还是用Inter的呢,我学艺术设计的要雪CAD3DMAX等等CPU用AMD的还是用Inter的呢。前 言 毕

资讯

浮头式换热器毕业论文

阅读(86)

本文主要为您介绍浮头式换热器毕业论文,内容包括求毕业论文:浮头式换热器设计说明书,换热器毕业设计,浮头式换热器制造工艺。浮头式换热器浮头式换热器两端的管板,一端不与壳体相连,该端称浮头。管子受热时,管束连同浮头可以沿轴向自由伸缩,完全

资讯

机座数控毕业论文

阅读(80)

本文主要为您介绍机座数控毕业论文,内容包括数控技术毕业论文怎么写数控技术毕业论文,我想要一个关于《数控毕业的论文》,谁有数控专业的毕业论文。数控铣刀的分类及应用的研究 摘共l数控行业的空前发展,使数控铣刀样式萦多,对其进行合理划分

资讯

关于erp的毕业论文

阅读(79)

本文主要为您介绍关于erp的毕业论文,内容包括求ERP系统毕业论文,求ERP系统毕业论文,erp毕业论文该怎么写啊。包括论文,设计,论文字数:16137,页数:40 摘要ERP(Enterprise Resources Planning,企业资源计划)

资讯

美术学师范毕业论文

阅读(85)

本文主要为您介绍美术学师范毕业论文,内容包括师范美术专业毕业论文怎么写啊,我是美术学专业国画方向的,过段时间要写毕业论文了,想在近期确,美术鉴赏论文1000到1500字,急求。论文题目:要求准确、简练、醒目、新颖。2、目录:目录是论文中主要

资讯

农村土地流转毕业论文

阅读(76)

本文主要为您介绍农村土地流转毕业论文,内容包括主题为:农村土地流转情况(三千字论文),农村家庭土地流转的论文该怎么写啊范围太大,到底是要,对于土地流转的论文下面的参考文献怎么写。摘要:农村土地流转问题一直是影响农村经济发展的关键因素

资讯

毕业论文字体格式要求国标

阅读(90)

本文主要为您介绍毕业论文字体格式要求国标,内容包括论文的标准格式和字号要求,毕业论文的所有的字号要求是什么,论文格式字体有什么要求。给你个参考 本科生毕业论文(设计)格式要求 第一部分:扉页 论文题目(黑体二号,居中);其他填写内容在

资讯

兰州交通大学地下连续墙毕业论文

阅读(73)

本文主要为您介绍兰州交通大学地下连续墙毕业论文,内容包括求一份关于"地下连续墙施工技术“的完整论文,或者关于地下连续,浅谈地下连续墙施工技术,浅谈地下连续墙施工技术。地下连续墙施工工艺 A地下连续墙施工工艺地下连续墙施工主要施工

资讯

毕业论文培训提纲

阅读(79)

本文主要为您介绍毕业论文培训提纲,内容包括我要写一篇人力资源管理的毕业论文,关于培训的,求一个提纲搜狗,毕业论文的提纲都需要写什么,毕业论文提纲。67. 智联招聘网络甄选体系设计(字数:9293,页数68. 论企业核心竞争力(字数:5137,页数:07 :)69.

资讯

交通运输专业毕业论文题目

阅读(88)

本文主要为您介绍交通运输专业毕业论文题目,内容包括交通运输毕业论文题目,交通运输大类毕业设计与论文题目来源是什么呢,求论文《我对交通运输专业的认识》。(一)确定论文提要,再加进材料,形成全文的概要论文提要是内容提纲的雏型。一般书、教